GRP pipes
 

News :


Sarplast Tools are a set of helpful programs for checking and designing GRP pipelines. The current version 1.0 is composed by three modules for the following tasks:


Sarplast Tools: una serie di utili programmi per la progettazione e la verifica delle tubazioni in GRP.
La versione attuale č la 1.0 ed č composta da 3 moduli con le seguenti funzionalitą:

Hydraulic calculations / Calcolo idraulico

Full Bore:
The program is based on the Darcy-Weisbach equation, with Colebrook friction factor.
It evaluates the head losses from the diameter and flow velocity, or velocity and flow volume, or diameter, from the input of the other available data.
The friction factor is calculated from the pipe wall roughness, the fluid kinematic viscosity and from the joint type and spacing.
The unit loss (shown as m/km) cumulates the losses due to the joints.
Two special input boxes for the whole pipeline length and for the total fitting coefficient for elbows, valves etc. are available in the input screen. The program calculates the total loss in the pipeline (in meters of liquid column).

. Sezione Piena:
Il programma, basato sulla formula di Darcy Weisbach con coefficiente di scabrezza di Colebrook, calcola le perdite di carico una volta dati diametro e velocitą (oppure la velocitą e portata, oppure il diametro, essendo noti gli altri dati).
Per la determinazione del coefficiente di attrito il programma tiene conto, oltre che della scabrezza della parete del tubo, anche del tipo di giunto e della sua spaziatura, e naturalmente della viscositą del fluido.
La perdita di carico unitaria esposta tiene gią conto delle perdite dovute ai giunti. E' possibile definire la lunghezza totale della condotta e un coefficiente globale (SK) per perdite localizzate dovute a curve, valvole ecc. Il programma calcola la perdita totale (in metri di colonna di liquido)

Flow with a free surface:
Pipe diameter and pipeline slope (in m/km) are given. The program computes the flow velocity and volume, for different filling height of the section.
Only a few major results are shown on the screen, while in the output print the geometric characteristics of the section, and velocity and flow volume are listed for filling from 5% to 100% at 5% steps.
The maximum flow volume is for 95% filling, the maximum velocity for 80% filling.
Also this program uses the Darcy-Weisbach equation with Colebrook friction factor.

Flusso a Pelo Libero
Dati diametro e pendenza della condotta (espressa in m/km) viene calcolata la portata a diverse altezze di riempimento della sezione.
Mentre a video sono mostrati solo alcuni valori significativi, in fase di stampa sono listate le caratteristiche geometriche della sezione e velocitą e portata per riempimenti dal 5% al 100% con salti del 5%.
La massima portata corrisponde approssimativamente a quella per il riempimento del 95%, mentre la massima velocitą si ha per un riempimento pari all'80%.
Il programma utilizza ancora la formula di Darcy con coefficiente di Colebrook.

Safety checking / Controlli di sicurezza

AWWA M45: (determining the minimum Pressure Class and Stiffness Class for buried GRP pipes)
The program is based on the recommendations of AWWA M45 Manual.
Its aim is to find the minimum pressure class and the minimum stiffness class required to fulfill the minimum AWWA safety conditions.
The program considers the working pressure and the surge pressure for water hammer in order to determine the Pressure Class. If the surge pressure is a normal design condition, it should be added to the working pressure. The minimum stiffness class (that can't be lower than 1250Pa) is determined from the limitation of the deflection (shortening of the vertical diameter due to external loads) to 5% of the diameter and from the fullfilment of the safety conditions against the buckling (elastic stability). The buckling check covers also the internal vacuum checking.
The installation conditions are outstanding for a flexible pipe such as GRP pipe, and the program allows to define them very precisely.

Determinazione delle minime classi di pressione e rigidezza per tubazioni interrate in PRFV
Il programma č basato sulle raccomandazioni del Manuale AWWA M45 e determina la minima classe di pressione e la minima rigidezza trasversale del tubo necessarie per soddisfare i requisiti minimi di sicurezza consigliati dal manuale AWWA.
Il programma tiene conto della pressione di esercizio e della sovrappressione dovuta al colpo d'ariete per determinare la classe di pressione minima necessaria.
Per la determinazione della minima rigidezza trasversale (comunque mai inferiore a 1250 Pa) si tiene conto sia della limitazione della deflessione al 5% del diametro (schiacciamento del diametro verticale del tubo sotto carichi distorcenti) sia della sicurezza nei confronti di fenomeni di instabilitą (collasso della tubazione per superamento del carico critico). Per questa seconda condizione si tiene conto anche del vuoto interno.
Le condizioni di installazione e interramento sono particolarmente importanti per tubazioni flessibili come quelle in PRFV, e il programma consente di definirle con precisione.
 

Click here to download Sarplast Tools / cliccate qui per scaricare i Sarplast Tools
Bilingual version / Versione bilingue (Windows 95/98/NT/Me/2000/XP) - 2.117 KB